120…240/277 V
90…305 V
0.55 A
47…63 Hz
0.95
Full load at 230 V/50 Hz
< 10 %
8.5 W
52 A
3
6
9
10 kV
5 kV
105 W
105 W
92 %
at 230 V, 50 Hz
500…1050 mA
700 mA
±5 %
10 %
≤1
≤0.4
100 mA
double/reinforced
170 V
75…150 V
153.6 mm
68.0 mm
37.0 mm
142.6 mm
34.0 mm
700.00 g
1.0 mm²
1.0 mm²
10 mm
300 mm
350 mm
300 mm
-40…+60 °C
Input voltage 200 – 277V, for Input voltage < 200V max. ta = 50°C
-40…+80 °C
85 °C
110 °C
5…85 %
Maximum 56 days/year at 85 %
50000 / 100000 h
At maximum Tc = 85°C / 10% failure rate / At maximum Tc = 75°C / 10% failure rate
Yes
2DIM / 1…10 V / AstroDIM
10…100 %
I
Programmable
No
Automatic reversible
Yes
No
2.0 m
Output wires must be routed as close as possible to each other
1
OT PROGRAMMER/5
No
IP67
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 62384/Acc. to EN 62386/GB 19510.1/GB 19510.14/GB 17625.1/UL-8750/FCC part 15/SASO 2927:2019
CCC / CE / ENEC / UL
850440829000
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
25-04-2022
4062172158169
Lead
7439-92-1
The identification of the Candidate List substance is sufficient to allow safe use of the article.
c3aac8b6-b2aa-4c53-a9da-bb86f91a55a6