Technical Data
Electrical data
Nominal input voltage
220…240 V
Mains frequency
50/60 Hz
Input voltage AC
198…264 V
Current set
DipSwitch
Power factor λ
0.95
Efficiency in full-load
89 %
Device power loss
9.7 W
Inrush current
60 A
Max. ECG no. on circuit breaker 10 A (B)
7
Max. ECG no. on circuit breaker 10 A (C)
12
Max. ECG no. on circuit breaker 16 A (B)
12
Max. ECG no. on circuit breaker 16 A (C)
20
Max. ECG no. on circuit breaker 25 A (B)
18
Max. ECG no. on circuit breaker 25 A (C)
31
Surge capability (L/N-Ground)
2 kV
Surge capability (L-N)
1 kV
Nominal output voltage
27…51 V
Nominal output current
1300 / 1400 / 1500 / 1600 mA
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
35.1…81.6 W
Maximum output power
81.6 W
Output current tolerance
±7.5 %
Galvanic isolation
SELV
Total harmonic distortion
< 20 %
Output ripple current (100 Hz)
< 10 %
U-OUT (working voltage)
< 60 V
Dimensions & weight
Mounting hole spacing, length
270.0 mm
Product weight
210.00 g
Cable cross-section, input side
0.5…1.5 / 0.75…1.5 mm²
Cable cross-section, output side
0.5…1.5 / 0.75…1.5 mm²
Wire preparation length, input side
7…8 mm
Length
280.0 mm
Wire preparation length, output side
7…8 mm
Height
21.0 mm
Width
30.0 mm
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-20…+50 °C
Maximum temperature at tc test point
75 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-40…85 °C
Permitted rel. humidity during operation
5…90 %
Lifespan
ECG lifetime
35000 / 50000 h
Additional product data
Encapsulated
No
Capabilities
Dimmable
No
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Suitable for fixtures with prot. class
I
Number of channels
1
Avaliações
Não há avaliações ainda.